The FDA has approved InspireMD’s CGuard Prime stent system for use in transcarotid artery revascularization, or TCAR, a less invasive procedure to open narrowed neck arteries and help prevent strokes, the company announced Nov. 12, TipRanks reported. The approval, granted as a supplement to the device’s existing approval, covers an 80-centimeter version of the system used with an embolic protection system.
The decision rests on a single-arm trial of 50 patients at 11 U.S. sites. At 30 days, the company reported 100% acute device success and no deaths, strokes, heart attacks, or stent clots.
For older adults with severe carotid artery narrowing who are considered too risky for traditional neck surgery, the approval adds another stent option to an established procedure. But the trial was small and short, and its results come from the company.
TCAR in Plain Terms
The carotid arteries on each side of the neck carry blood to the brain. Plaque buildup can narrow them, and pieces of plaque can break loose and cause a stroke.
In TCAR, a surgeon makes a small incision at the neckline just above the collarbone, the Society for Vascular Surgery explains. Blood flow in the artery is temporarily reversed so that loose debris is pulled away from the brain while a stent is placed. Then normal flow is restored.
The traditional alternative, carotid endarterectomy, removes plaque through a longer neck incision. Potential risks of TCAR include stroke, heart attack or death, damage to the artery or a cranial nerve, and bleeding, bruising or swelling at the neck incision, according to the society. TCAR may be recommended for people whose age, anatomy, or other conditions make open surgery riskier. The company estimates more than 35,000 TCAR procedures are performed in the U.S. each year.
CGuard Prime is covered by a fine mesh, which InspireMD calls MicroNet, designed to trap plaque against the artery wall. The FDA approved the device in June 2025 for stenting performed through a catheter, based on a 316-patient trial, Cardiovascular Business reported.
Evidence Check: Encouraging, Small and Company-Reported
The TCAR trial, called CGUARDIANS II, enrolled 50 patients in a single-arm design. It had no comparison group, so it cannot show that CGuard Prime performs better than other stents used in TCAR.
Fifty patients are too few to reliably detect uncommon complications, and 30 days is too short to judge long-term stroke prevention. The results announced so far come from the manufacturer and have not been published in a peer-reviewed journal.
Device history is worth noting too. In May 2026, InspireMD recalled a longer 135-centimeter CGuard Prime delivery system after it failed to meet performance expectations, MassDevice reported. That recall involved a different length of the delivery system, not the 80-centimeter TCAR version now approved.
InspireMD also points to its earlier 316-patient C-GUARDIANS trial, which reported major adverse event rates of 0.95% at 30 days and 1.93% at one year, figures the company describes as the lowest of any pivotal carotid stenting study.
Carotid stenting has gained ground more broadly. In the NIH-funded CREST-2 trials, adding stenting to intensive medical therapy cut the four-year risk of stroke from about 6% to just under 3% in people with severe narrowing who had not had a recent stroke, according to University of Utah Health, a trial site. In the parallel surgery trial, endarterectomy did not show a statistically significant benefit over medical therapy alone.
Those CREST-2 results involved stenting in general, not CGuard Prime or TCAR specifically. They help explain why interest in less invasive carotid procedures is growing.
Patients Who May Be Candidates
TCAR is typically considered for people with significant carotid narrowing who have had stroke symptoms, or who have severe narrowing without symptoms, and who face higher risks from open surgery. That includes older adults and people with heart disease, prior neck surgery or radiation, or difficult anatomy.
Many people with carotid narrowing do well with medicines alone, including blood pressure control, cholesterol-lowering drugs and antiplatelet therapy. The right choice depends on symptoms, the degree of narrowing and overall health, and should be made with a vascular specialist.
Most TCAR patients spend one night in the hospital, according to the Society for Vascular Surgery. Patients still need follow-up imaging and medicines to prevent clots in the treated artery.
Patients can ask their surgeon how many TCAR procedures they perform, which stent they use and why, and what the expected recovery looks like. Asking whether insurance covers the procedure and device before scheduling can prevent surprise bills.
Stroke Warning Signs Still Come First
Carotid disease often causes no symptoms until a stroke or mini-stroke occurs. Sudden facial drooping, arm or leg weakness on one side, trouble speaking, sudden vision loss in one eye or severe dizziness need a 911 call right away, even if symptoms fade.
People with risk factors such as high blood pressure, diabetes, smoking, or vascular disease elsewhere can ask their doctor whether they need carotid screening.
Longer-term CGUARDIANS II results and real-world data will show how the device performs beyond 30 days. MedicalDaily will report when those results are released.
Key Questions Answered
What did the FDA approve? The CGuard Prime 80-centimeter stent system for use in TCAR procedures to treat carotid artery narrowing.
What is TCAR? A procedure that uses a small neck incision and temporary reversal of blood flow to place a stent while protecting the brain from debris.
What did the trial show? In 50 patients, the company reported no deaths, strokes, heart attacks, or stent clots within 30 days.
What are the limits of the evidence? The trial was small, single-arm, short-term, and company-reported.
Who might be a candidate? People with significant carotid narrowing who face higher risks from traditional open surgery.
What are stroke warning signs? Facial drooping, one-sided weakness, trouble speaking, sudden vision loss, or severe dizziness. Call 911.